Bilge pumps are the boring stuff nobody looks at, until the day you really need them. On Vira the manual pump hadn't seen service since the boat was built, and the big electric one had a sneaky habit of running without moving any water. Here's how both got fixed. The little "dry bilge" pump that keeps the last drops out is in Small electronics projects.
The manual bilge pump
The manual bilge pump looked like nobody had serviced it since the boat was built. The diaphragm was dried out, and it wouldn't prime at all. I rebuilt it, put it back, and now it self-primes well.
The main bilge pump
In 2026 I put the main bilge pump switch back, and later added a 1/2-inch spacer under it, because the pump didn't have enough water to start pumping. I measured the bilge for an emergency pump: 9 inches deep at most.
My main bilge pump is a serious one, 3,800 GPH. But there was one small problem. The discharge has an inline check valve, so water doesn't run back after the pump stops, and the hose is long. The previous owner set it up that way. Sometimes, especially after my small "dry bilge" pump had taken out every last drop and then water collected up to the switch level, the big pump got airlocked. It ran perfectly fine but moved no water, because it couldn't prime. I don't like that failure mode: right when you need the pump most, it sits there spinning without moving a drop.
There were two options. Remove the check valve: no airlock, but every time the pump stops, about two gallons run back into the bilge, and seawater could come back through the discharge when the boat heels hard. Or give the trapped air a way out before the pump moves water, at the cost of a little pumped water going back to the bilge. I chose the second. I drilled a small air-bleed hole in the discharge hose between the pump and the check valve, and designed and printed a little cover that sends any bleed water back down into the bilge, held on with a zip tie. Simple, cheap, and hopefully one less surprise.